doing it with your own power
Members: 219
Latest Activity: Feb 20, 2017
Started by Kimberly Irene Lewis. Last reply by Jim Edmunds Feb 20, 2017. 7 Replies 0 Likes
Hi I am new and just researching my systems before I put them in. I plan on eventually having at least one large greenhouse full of aquaponics. I Live in Virginia and where as it doesn’t get too cold…Continue
Started by William Kohut. Last reply by Jim Fisk Jan 29, 2016. 8 Replies 0 Likes
Has anyone built a Windmill for aeration ? I am looking for plans to build a windmill and an aerator that runs off it.Continue
Started by Jeffrey Ihara. Last reply by Jeff S Sep 20, 2015. 29 Replies 0 Likes
So I bought a 45W photovoltaic kit from Harbor Freight which comes with its own charge controller ($139 on sale), a used deep cycle battery with 135 amp-hours, and a 1.6 amp DC pump that moves over…Continue
Started by Carla&Dave. Last reply by Carla&Dave Jun 25, 2015. 4 Replies 0 Likes
Pump power load on my SAP (Solar Aquaponics) system - rough calcs: I just put the system up last week, and just put in a kill-a-watt meter on Sunday.The meter is showing 200 watt hours in 24 hours…Continue
Comment
Debra: No, but I do run a DC water pump from solar charged 12-volt batteries. It has been running non stop for a few weeks now. It's a 250 GPH or thereabouts Rule 24. I may run my system entirely with 12-volt DC at some point.
I am interested to test dc items. give me a website and I will order them
I was asked about using one PV panel to start the learning. I did order 2 PV panels to start my learning.. BUT that was a waste of money for shipping. I believe you can ship 1 PV panel for about the same expense as 4 PV panels. You will find other items that you will want to run on solar, after you get started.
I initially measurted each pump, but I changed things around and I have lost track. So, I do not have a meter reading for each pump. My solar setup is handeling 2 grow-beds and 2 fish tanks. each bed has one pump for water. I have 3 aeriators. all totaled I am running a little more than 100 watts, according to a sensor built into the inverter. So, any time that I am over 4 watts (from the PV panel) I putting a trickel charge into the battery bank of 8 115 amp batteries. I have noticed as much as 14 amps from the PV panel going into the controller.
Just got this back from Aire-Dynamics
If there is a 30 kilometer/hr wind, the
windmill will store about 2 bar of
pressure. Less if the wind is lighter.
Once that pressure has been achieved,
the windmill will stop and not start
back up until the pressure is bled off.
I won't recommend trying to store the
compressed air. You can use the air
when the wind blows but it's best
if you have power backup. It would take
an extremely large tank to store
enough compressed air to make up
for times when there is little or no wind.
It also would take a very long
time to fill a very large tank to the
pressure needed.
I guess we wont know unless we keep asking and keep looking for
better ways.
Still waiting to hear back from a high tech windmill company...
My reason for saying the 33 vdc panel is not a good choice is because I wanted to use a 12vdc setup. the price is good, but it is a waste of power.. My thought.
Dave: What is the draw of your pump and how much are you pumping? Anything normally running from the solar system other than one pump?
this is a 24/7 project. this is all new for me, but I am learning fast.
8 115 amp deep cycle batteries ($99.00 ea) from AutoZone
2 235 watt 33vdc PV panels, not a good choice, ($1.21 per watt) Affordable Solar
Go Power inverter from Amazon.com
Xantrex C-60 controller from ebay.com